Jul 15, 2010 · 2009 IRCI see no minimum door sizes for bedrooms... or other rooms for that matter. The only door with prescribed dimensions is the one required egress door to the outside (IRC 311.2)
less than 32" Door size - The Building Code Forum
Oct 31, 2014 · I know the egress doors shall be not less than 32" bu how about bathroom door or walk-in closet door? thank you!
Residential Door Locks 06 IRC Section R311.4.4 - The Building …
Oct 25, 2012 · The egress door shall be side-hinged, and shall provide a minimum clear width of 32 inches when measured between the face of the door and the stop, with the door open 90 degrees.
IRC Required Exit Door Question - The Building Code Forum
Oct 12, 2010 · It is my understanding that if a builder chooses to use a twin swinging door unit confiquration designated as the required exit door for a residence, that the primary door within the twin unit must have a minimum width of 36". In other …
Single step at bedroom door permitted? - The Building Code Forum
Oct 10, 2016 · The width perpendicular to the direction of travel shall be not less than the width of the flight served. Landings of shapes other than square or rectangular shall be permitted provided that the depth at the walk line and the total area is not less than that of a quarter circle with a radius equal to the required landing width.
Door size from house to garage - The Building Code Forum
Aug 17, 2020 · I'm new to this forum, but not new to the headache of trying to find code find & what will pass inspection for my Remodel. I currently have no door from house into the garage. I asked the building inspector if I could install a door leading from the house into garage without resubmitting my...
Hotel Bathroom Pair of Doors - The Building Code Forum
Oct 20, 2009 · The maximum width of a swinging door leaf shall be 48 inches (1219 mm) nominal. Means of egress doors in a Group I-2 occupancy used for the movement of beds shall provide a clear width not less than 41 1/2 inches (1054 mm). The height of door openings shall not be less than 80 inches (2032 mm). Exceptions:1.
Basement stair width code?? - The Building Code Forum
Feb 25, 2019 · 2) Bedroom door recesses (in basement) too narrow, so that doors won't swing fully open into them (doors bumps corner of recesses). Problem is, these are unfixable, since you can't move walls after construction.
Water closet / toilet room size and entry question. - The Building …
May 2, 2021 · Unless there is an amendment to your California Code, there is no requirement for the size of your toilet room, as long as the fixtures you are placing within, meet their minimum dimensions; 30" width for water closet and 24" clear in front of the bowl. As for the door width, the 28" door, although not the best practice as mentioned, unless there is a code amendment, the …
Stair front door distance Q - The Building Code Forum
Oct 28, 2009 · If my interp on the layout is correct, the 24" distance is fine, because you have the 24 plus the width of the entry door area as your landing, the code allows the door to enter from a side across a stair, think of the IBC and every stair tower built. Correct me if …